Limit - Keysight x-series User Reference Manual

Signal analyzer
Hide thumbs Also See for x-series:
Table of Contents

Advertisement

Preset
State Saved
Range
Initial S/W Revision

Limit

Enables you to set the desired limit.
Key Path
Remote Command
Example
Preset
State Saved
Min
Max
Initial S/W Revision
Attenuation
Enables you to set the value of the Attenuation parameter. This key only affects the Mechanical
Attenuator.
The following amplitude parameters are not settableby the user and therefore do not appear in any
menus:
Elec Attenuator
Elec Attenuation
Meas Atten Step
Max Mixer Level
EMI Receiver Mode Reference
MAINS
Saved in instrument state
Mains | Load | Motor Power 1 <= 700 W | Motor Power 2 700 W < MP <= 1000 W | Motor Power  3
> 1000 W
A.14.00
Meas Setup, Setup Table
CALCulate:DANalyzer:LIMit <amptd>
CALCulate:DANalyzer:LIMit?
CALCulate:DANalyzer:LIMit:AUTO ON|OFF|1|0
CALCulate:DANalyzer:LIMit:AUTO?
CALC:DAN:LIM 50 dBuV
CALC:DAN:LIM?
CALC:DAN:LIM:AUTO OFF
66
ON
Saved in instrument state
6.99 dBuV
156.99 dBuV
A.14.00
Disabled
0dB
2dB
–10dBm
12  Disturbance Analyzer Measurement
Meas Setup
1067

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pxa n9030aMxa n9020aExa n9010aCxa n9000aEmi n9038a

Table of Contents