Amplitude Correction

Pressing this key selects Amplitude Corrections as the data type to be exported. Pressing this key again
brings up the Select Menu, which allows the user to select which Amplitude Correction to save.
Amplitude Corrections are fully discussed in the documentation of the Input/Output key, under the
Corrections softkey.
See
"Correction Data File " on page 1101
Key Path
Remote Command
Example
Notes
Dependencies
Readback
Backwards
Compatibility SCPI
Initial S/W Revision
Correction Data File
A Corrections Data File contains a copy of one of the analyzer correction tables. Corrections provide a way
to adjust the trace display for predetermined gain curves (such as for cable loss).
Corrections files are text files in .csv (comma separated values) form, to make them importable into Excel
or other spreadsheet programs.   The format for Corrections files is as follows. 
Line
#
Type of field
1
File type, must be "Amplitude
Correction"
2
File Description (in quotes)
3
Comment (in quotes)
EMI Receiver Mode Reference
Save
:MMEMory:STORe:CORRection 1|2|3|4|5|6, <filename>
:MMEM:STOR:CORR 2 "myAmpcor.csv" saves Correction 2 to the file myAmpcor.csv on the current
path.
The default path is My Documents\amplitudeCorrections.
If the save is initiated via SCPI, and the file already exists, the file will be overwritten.
Using the C: drive is strongly discouraged, since it runs the risk of being overwritten during an
instrument software upgrade.
Both single and double quotes are supported for any filename parameter over SCPI.
Corrections are not supported by all Measurements. If in a Mode in which some Measurements
support it, this key will be grayed out in measurements that do not. The key will not show at all if no
measurements in the Mode support it.
This key will not appear unless you have the proper option installed in your instrument.
Selected Correction
:MMEMory:STORe:CORRection ANTenna | CABLe | OTHer | USER, <filename>
For backwards compatibility, ANTenna maps to 1, CABle maps to 2, OTHer maps to 3 and USER
maps to 4
A.02.00
Example
Amplitude Correction
"Correction Factors for 11966E"
"Class B Radiated"
12  Disturbance Analyzer Measurement
Notes
May not be omitted
60 characters max; may be empty but
may not be omitted. If exceeds 60
characters,  error –233 Too much data
reported
60 characters max;  may be empty but
Save
1101