D-Link DXS-3600-16S Manual page 593

Dxs-3600 series layer 2/3 managed 10gbe switch
Hide thumbs Also See for DXS-3600-16S:
Table of Contents

Advertisement

60-3 logging console
This command is used to set the severity of logs that are allowed to be displayed on the console. The no format of the
command disable show log on console.
logging console LEVEL
no logging console
Parameters
LEVEL
Default
Command Mode
Command Default Level
Usage Guideline
Severity
Emergency
Alert
Critical
Error
Warning
Notice
Information
Debug
Example
DXS-3600-32S#configure terminal
DXS-3600-32S(config)#logging console informational
DXS-3600-32S(config)#
60-4 logging trap
This command is used to set the severity of logs that are allowed to be send to the syslog server. The no format of the
command disable send log to syslog server.
logging trap LEVEL
no logging trap
Parameters
LEVEL
Default
Command Mode
Command Default Level
DXS-3600 Series 10GbE Layer 2/3 Switch CLI Reference Guide
Specifies the severity of log messages, 0 to 7. The name of the severity or the
numeral can be used.
Debugging level.
Global Configuration Mode.
Level: 15
When a log severity is set here, the log messages at or below that severity will be
displayed on the console.
The following table is description about the level:
Level
Description
0
System is unusable.
1
Action must be taken immediately.
2
Critical conditions.
3
Error conditions.
4
Warning conditions.
5
Normal but significant condition.
6
Information messages.
7
Debug-level messages.
This example shows how to set the severity of the log, that is allowed to be displayed
on the console, as 6:
Specifies the severity of log messages, 0 to 7. The name of the severity or the
numeral can be used.
Informational level.
Global Configuration Mode.
Level: 15