Example
DXS-3600-32S#show rmon history
Entry : 1
Data Source : 1.3.6.1.2.1.2.2.1.1.1
Buckets Requested : 50
Buckets Granted : 50
Interval : 30
Owner : monitor
Sample : 15
Interval Start : 45103
DropEvents : 0
Octets : 0
Pkts : 0
BroadcastPkts : 0
MulticastPkts : 0
CRCAlignErrors : 0
UndersizePkts : 0
OversizePkts : 0
Fragments : 0
Jabbers : 0
Collisions : 0
Utilization : 0
Sample : 16
Interval Start : 48103
DropEvents : 0
Octets : 0
CTRL+C ESC q Quit SPACE n Next Page ENTER Next Entry a All

51-7 show rmon alarm

This command is used to display alarm information.
show rmon alarm
Parameters
Default
Command Mode
Command Default Level
Usage Guideline
Example
DXS-3600-32S#show rmon alarm
Alarm : 1
Interval : 100
Variable : 1.3.6.1.2.1.16.1.1.1.14.1
Sample Type : delta
Last Value : 0
Startup Alarm : 3
Rising Threshold : 10000
Falling Threshold : 1000
Rising event : 1
Falling event : 1
Owner : test
DXS-3600-32S#
DXS-3600 Series 10GbE Layer 2/3 Switch CLI Reference Guide
This example shows how to display the RMON history entry.
None.
None.
Privileged EXEC Mode.
Level: 3
Alarm is the third group in RMON. It monitors a specific management information
base (MIB) object at the specified interval. When the value of this MIB object is
higher than the predefined upper limit or lower than the predefined lower limit, an
alarm will be triggered. The alarm is handled as an event by means of recording the
log or sending the SNMP Trap message.
This example shows how to display the RMON alarm information.