Maintenance Commands
change synchronization
Use change synchronization to specify the hierarchy of sources used for timing
synchronization. DS1 inputs to the external stratum 3 clock affect stratum 3
synchronization hierarchy. Primary and secondary fields reflect Stratum 4
synchronization. If all fields are blank, the tone clock board within each PN
provides timing for that PN.
Action/Object
Qualifier
change
synchronization
Output/Input
The following example shows the output for change synchronization with 4
entered in the Stratum field.
change synchronization
SYNCHRONIZATION SOURCE (circuit pack location)
Stratum: 4
Primary: _____
Location
Name
NOTE: DS1 and BRI trunk sources will result in stratum 4, type II ynchronization
The following example shows the output for change synchronization with 3
entered in the Stratum field.
change synchronization
SYNCHRONIZATION SOURCE (DS1 circuit pack location)
Stratum: 3
Port Network: 1
184
Issue 5 October 2002
Qualifier Description
Examples:
change
synchronization
change synch
SYNCHRONIZATION PLAN
Secondary: _____
Slip
Location
SYNCHRONIZATION PLAN
Logins
Default
Feature Interactions
init
none
DS1 interface, BRI trunk, or
inads
UDS1 board selected as a
craft
primary or secondary synch
cust
source cannot be removed
rcust
on the DS1 circuit pack
bcms
administration form or the
regular circuit pack
administration form.
Name
Slip
Page
1 of
1
Page
1 of
1
555-233-119
Need help?
Do you have a question about the DEFINITY Server CSI and is the answer not in the manual?