cancel hardware-group
cancel hardware-group
Use cancel hardware-group to temporarily or permanently abort the execution of
test hardware-group.
To resume testing, use resume hardware-group or test hardware-group.
Action/Object
Qualifier
cancel
hardware-group
Feature Interactions
Scheduled and Periodic Maintenance
When test hardware-group is entered, all activity related to scheduled
background maintenance, periodic background maintenance, and data
audits stops for the duration of test hardware-group test. All activity
related to scheduled background maintenance, periodic background
maintenance, and data audits restarts when test hardware-group is
canceled.
Status Hardware-group
Use status hardware-group to show the state of a canceled test
hardware-group command as canceled.
change circuit-packs
Use change circuit-packs to administer circuit packs that are inserted into the
system port, expansion control, and switch node carriers. It configures the system
when circuit packs are not physically inserted.
Action/Object
Qualifier
change
cabinet
circuit-packs
number
Output
The following is an example of page 1 of change circuit-packs 1 when
EMBEDDED AUDIX is administered with TN566 in slot 8.
555-233-119
Qualifier Description
Examples:
cancel hardware-group
Qualifier Description
Cabinet number of circuit
packs to change
Examples:
change circuit-packs 1
change circuit-packs 2
Logins
Defaults
Feature Interactions
init
none
See below
inads
Logins
Default
Feature Interactions
init
1
none
inads
craft
cust
nms
Issue 5 October 2002
179
Need help?
Do you have a question about the DEFINITY Server CSI and is the answer not in the manual?