Maintenance Commands
busyout sp-link
Use busyout sp-link to put the system printer link into a maintenance busy state.
This prevents access to the system printer. The system printer link is a link from
the system to an external printer. The system printer extension is administered
and a call is set up to the system printer.
Output
The following is an example of the results of busyout sp-link.
.
busyout sp-link
Port
Maintenance Name
SYS-PRNT
busyout station
Use busyout station to place the installed and uninstalled administered station in
a maintenance busy state. No periodic or scheduled tests are performed on the
busied out station until it is released. When a station is maintenance busy it is
deactivated, and no call processing activity may include the busied object.
Warning alarms (error type 18) are generated on each busied out maintenance
object, so that INADS can determine the state of the objects.
Use release station to reactivate the voice terminal extension.
Action/Object
Qualifier
busyout
extension
station
Output
The following example is a display of busyout station.
174
Issue 5 October 2002
COMMAND RESULTS
Alt. Name
Qualifier Description
Extension number (per dial-plan)
Examples:
busyout station 10020
busyout station 32770
Result
Error Code
PASS
Logins
Default
init
none
inads
craft
Feature Interactions
none
555-233-119
Need help?
Do you have a question about the DEFINITY Server CSI and is the answer not in the manual?
Questions and answers