Avaya DEFINITY Server CSI Maintenance Manual page 188

Table of Contents

Advertisement

Maintenance Commands
Indicates if remote access testing on the SYSAM circuit pack is active.
Test Remote
Access Port
Enter y to maintain alarm origination capability when an INADS line is
connected to the switch and a maintenance contract is in effect.
If no equipment is connected to the remote access port, or if a trunk for
remote access and alarm origination is not provided, running tests on
the remote access port on the SYSAM results in test failures. This
causes unnecessary maintenance alarms and allows potentially
destructive tests to be run. To prevent this, set this field to n.
Indicates the minimum level (Major, Minor or Warning) to activate
CPE Alarm
Activation
Customer-Provided Equipment (CPE) alarm. If the level is none, the
Level
CPE does not activate for any alarm.
Enter y, to indicate to maintenance software that a Packet Control
Packet Bus
Activated
circuit pack is installed.
Enter y after a packet control circuit pack is installed and if packet
endpoints (for example, ASAI, and/or BRI) are administered, and
maintenance testing runs on both the Packet Control circuit pack and
Packet Bus.
If a Packet Control circuit pack is not installed in the system, a major
alarm is raised against the PKT-CTRL MO.
Enter n if no packet endpoints are administered. This ensures that no
packet endpoints can be administered if the packet bus deactivated.
Enter n if a Packet Control circuit pack is not installed, unless system
translations do not have all the required hardware.
Avaya services has sole access to this field.
Customer
Access to
Enter n to prevent customer login ID access to system administration
INADS Port
and maintenance interface control.
Enter the number of minutes that the system must wait before
Repeat Dial
Interval (MMS)
attempting another call origination to an OSS. Lack of a far-end
acknowledgment triggers the timer.
Scheduled Maintenance
The hour and minute, in 24-hour notation, when daily scheduled
Start Time
maintenance starts
The hour and minute when scheduled daily maintenance stops. If daily
Stop Time
maintenance operations are not completed by this time, the system
notes the stopped sequence location and includes those operations
during the next scheduled daily maintenance.
188
Issue 5 October 2002
NOTE:
When the switch goes into Emergency Transfer, the CPE alarm
activates regardless of the CPE Alarm Activation Level setting.
555-233-119