Maintenance Commands
busyout data-module
Use busyout data-module to put the data module in a maintenance busy state,
even uninstalled data modules. No periodic or scheduled tests is performed on
the busied out data module or data channel until it is released and no call
processing can be executed on the data modules or over the data channels.
Warning alarms are generated (error type 18) on each maintenance object busied
out, so that INADS can access the state of the objects. The release data module
command returns the specified data module (or data channel) to operation.
On a system with the duplication option, a busyout of a Network Control Data
Channel (DATA-CHL) or a Processor Interface Port Data Channels (PI-PT) are
preserved across SPE interchanges. The data channel extension must be
released before the data channel can be brought back into service.
Action/Object
Qualifier
busyout
extension
data-module
Output
The following example shows the output from busyout data-module 300.
busyout data-module 300
Port
Maintenance Name
01C1103
DIG-LINE
Field descriptions
Port address (cabinet-carrier-slot-circuit) or data channel number
Port
The name of maintenance object
Maintenance Name
Alternate way to identify maintenance objects.
Alt. Name
If the Object is
station
trunk
private CO line
Test result: Pass, Abort, or Fail
Result
Numeric code explaining why the release failed or aborted. See the
Error Code
detailed list of the codes by test number for each MO.
166
Issue 5 October 2002
Qualifier Description
Extension number (per dial-plan)
Example:
busyout data-module 31300
COMMAND RESULTS
Alt. Name
Result
300
PASS
The field contains
extension
xxx/yyy (xxx = trunk group, yyy = member number
P/xxx (xxx = private CO line group number)
Logins
Default
Feature Interactions
init
None
None
inads
craft
nms
SPE A
Error Code
555-233-119
Need help?
Do you have a question about the DEFINITY Server CSI and is the answer not in the manual?
Questions and answers