Maintenance Commands
Output
The following shows the output for busyout journal-printer wakeup-log.
busyout journal-printer wakeup-log
Port
Maintenance Name
0
JRNL-LINK
Field descriptions
Physical object port address: 0 = wakeup log, 1 = pms log
Port
The name of the maintenance object
Maintenance Name
Not applicable
Alt. Name
Test result: Pass, Abort, Fail
Result
Numeric code explaining why the release failed or aborted. See the
Error Code
detailed list of the codes by test number for each MO.

busyout link

Use busyout link to place maintenance objects associated with a link in a
maintenance busy state. No periodic or scheduled tests are performed on the
busied out maintenance objects until they are released. The link is marked out of
service and is inaccessible to call processing. Warning alarms (error type 18) are
generated on each busied out maintenance object, so that INADS can determine
the state of the objects.
Use release link reactivates the objects.
Action/Object
Qualifier
busyout link
link-id
Output
The following example shows the output from busyout link 1. The responses
appear on a test-by-test basis with one line of data for each test result.
168
Issue 5 October 2002
COMMAND RESULTS
Alt. Name
Result
PASS
Qualifier Description
Processor Interface circuit pack
1a1 or 1b1 = 1 – 4
Processor Interface circuit pack
1a2 or 1b2 = 5 – 8
Example: busyout link 1
SPE A
Error Code
Logins
Default
Feature Interactions
init
none
none
inads
craft
555-233-119

Hide quick links: