busyout board

Output
The following example shows the output for busyout access-endpoint 22502
and assumes that access endpoint ports for extension 22502 are in cabinet 1,
carrier C, slot 11, circuit 1 to 6. The responses appear on a test-by-test basis with
one line of data for each test result.
busyout access-endpoint 22502
Port
Maintenance Name
01C1101
WAE-PORT
01C1102
WAE-PORT
01C1103
WAE-PORT
01C1104
WAE-PORT
01C1105
WAE-PORT
01C1106
WAE-PORT
Field descriptions
Port
Maintenance Name
Alt. Name
Result
Error Code
busyout board
Use busyout board to put all the ports associated with the specified access
endpoint in a maintenance busy (craft busy) state. No periodic or scheduled tests
are performed on the busied out access endpoint ports until they are released.
When the access endpoint ports are maintenance busy, the access endpoint is
removed from active service on the switch, meaning that no call processing
activity can include the busied objects because terminals on the administered
ports do not receive dial-tone. Warning alarms are generated on each busied out
port in the access endpoint. Use release access-endpoint to return all the ports
associated with the specified access endpoint to operation.
!
WARNING:
busyout board is service disrupting and may cause extraneous alarms.
555-233-119
COMMAND RESULTS
Alt. Name
22502
22502
22502
22502
22502
22502
Port address (cabinet-carrier-slot-circuit)
Name of maintenance object
WAE-PORT = wideband access endpoint
TIE-DS1 = single port access endpoint)
The extension number of the access endpoint.
Test result: Pass, Fail, Abort
Numeric code explaining why the release failed or aborted. See
the detailed list of the codes by test number for each MO.
SPE A
Result
Error Code
PASS
PASS
PASS
PASS
PASS
PASS