Show User Lockout-Setting - Alcatel-Lucent 060321-10, Rev. B Cli Reference Manual

Omniswitch series
Table of Contents

Advertisement

AAA Commands

show user lockout-setting

Displays the global user lockout settings for the switch.
show user lockout-setting
Syntax Definitions
N/A
Defaults
N/A
Platforms Supported
OmniSwitch 10K
Usage Guidelines
The global lockout settings include parameter values that determine the length of a user observation
window, the amount of time a locked user remains locked, and the number of failed password login
attempts allowed.
Examples
-> show user lockout-setting
Lockout Setting:
Observation window: 30 (minutes)
Duration: 200 (minutes)
Threshold: 20
output definitions
Observation window
Duration
Threshold
Release History
Release 7.1.1; command was introduced.
OmniSwitch CLI Reference Guide
The amount of time, in minutes, during which the number of failed
password login attempts are counted. Configured through the
lockout-window
command.
The amount of time, in minutes, that a locked user account remains
locked out of the switch. Configured through the
tion
command.
The maximum number of failed password login attempts allowed
before the user is locked out of the switch. Configured through the
lockout-threshold
March 2011
command.
show user lockout-setting
user
user lockout-dura-
user
page 28-53

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Omniswitch 10k

Table of Contents