qos log console

qos log console
Sends QoS log messages to the switch logging utility, which is an event logging application available on
the OmniSwitch. The configuration of the switch logging utility determines if QoS messages are sent to a
log file in the switch's flash file system, displayed on the switch console, or sent to a remote syslog server.
qos log console
qos no log console
Syntax Definitions
N/A
Defaults
QoS log messages are not sent to the switch logging utility by default.
Platforms Supported
OmniSwitch 10K
Usage Guidelines
To display QoS log events as they happen on an output console attached to the switch, configure the
switch logging utility to output events to the console. This is done using the swlog output command.
The entire log may be viewed at any time using the show qos log command.
Examples
-> qos log console
-> qos no log console
Release History
Release 7.1.1; command was introduced.
Related Commands
qos log lines
swlog output
swlog output
MIB Objects
alaQoSConfigTable
alaQoSConfigLogConsole
page 25-8
Configures the number of lines in the QoS log.
Enables or disables switch logging output to the console, file, or data
socket (remote session).