PIM Commands
ip pim invalid-register-notification-period
Specifies the minimum time that must elapse between the PIM invalid register notifications originated by
the router.
ip pim invalid-register-notification-period seconds
Syntax Definitions
seconds
Defaults
parameter
seconds
Platforms Supported
OmniSwitch 10K
Usage Guidelines
•
The default value of 65535 represents an infinite time. The PIM invalid register notifications are never
sent in case of infinite time.
•
The non-zero minimum allowed value provides resilience against the propagation of denial-of-service
attacks from the data and control planes to the network management plane.
•
This value is used with both IPv4 and IPv6 PIM.
•
This command is supported only in the sparse mode.
Examples
-> ip pim invalid-register-notification-period 100
Release History
Release 7.1.1; command was introduced.
Related Commands
show ip pim notifications
MIB Objects
alaPim
alaPimInvalidRegisterNotificationPeriod
OmniSwitch CLI Reference Guide
Specifies the minimum time value that must elapse between invalid
register notifications, in seconds (10–65535).
default
65535
Displays the configuration of the configured notification periods as
well as information on the events triggering the notifications.
March 2011
ip pim invalid-register-notification-period
page 23-33