Show Temperature - Alcatel-Lucent 060321-10, Rev. B Cli Reference Manual

Omniswitch series
Table of Contents

Advertisement

Chassis Management and Monitoring Commands

show temperature

Displays the ambient temperature of the current operating chassis, as well as current temperature thresh-
old settings.
show temperature [fabric [index] | slot [index] | fantray [index] | cmm [index | cmm_letter]]
Syntax Definitions
index
number
Defaults
N/A
Platforms Supported
OmniSwitch 10K
Usage Guidelines
N/A
Examples
-> show temperature
Device | Current |
-------+---------+---------+--------+-----------------
CMMA
45
FAB1
46
Slot1
43
Slot3
43
Slot4
43
output definitions
Device
Current
Range
Thresh
Status
Release History
Release 7.1.1; command introduced.
OmniSwitch CLI Reference Guide
Specifies the index number.
Specifies the slot number.
Range
| Thresh |
Status
15-60
55
UNDER THRESHOLD
15-60
55
UNDER THRESHOLD
15-60
55
UNDER THRESHOLD
15-60
55
UNDER THRESHOLD
15-60
55
UNDER THRESHOLD
The device being measured (i.e. CMM, Fabric, or NI)
The current CPU temperature in Celsius.
The supported threshold range.
The warning temperature threshold, in degrees Celsius. If the switch
reaches or exceeds this temperature, the primary switch or CMM's
TEMP LED displays amber and a warning is sent to the user.
Whether the current temperature has reached the threshold.