AAA Commands

show user lockout-setting

Displays the global user lockout settings for the switch.
show user lockout-setting
Syntax Definitions
N/A
Defaults
N/A
Platforms Supported
OmniSwitch 6250
Usage Guidelines
The global lockout settings include parameter values that determine the length of a user observation
window, the amount of time a locked user remains locked, and the number of failed password login
attempts allowed.
Examples
-> show user lockout-setting
Lockout Setting:
Observation window: 30 (minutes)
Duration: 200 (minutes)
Threshold: 20
output definitions
Observation window
Duration
Threshold
Release History
Release 6.6.1; command was introduced.
OmniSwitch 6250 CLI Reference Guide
The amount of time, in minutes, during which the number of failed
password login attempts are counted. Configured through the
lockout-window
command.
The amount of time, in minutes, that a locked user account remains
locked out of the switch. Configured through the
tion
command.
The maximum number of failed password login attempts allowed
before the user is locked out of the switch. Configured through the
lockout-threshold
command.