3.15 Changing the Output Status

The status of external output signals can be changed from the programming pendant by using
either of the following two methods.
• On the universal output status display (see " 5.2.2 Universal Output ")
• On the relay on display
The method that uses the relay on display, which is described here, simplifies the operation
for changing the status of signals that are used frequently.
A maximum of 16 output signals can be displayed on the relay on display and they must be
N OT E
set in advance with parameter settings S2C213 to S2C228.
Operation
Select {IN/OUT} under the top menu
*2
signal for changing
Explanation
*1
The relay on display is shown.
Select the status (* or ') of the desired signal to change.
*2
Select {RELAY ON}
Press [INTER LOCK]+[SELECT]
D A T A
EDIT
R E L A Y O N
OUTPUT NO.
STATUS
OUT#010
OUT#008
OUT#014
OUT#009
!
3-89
3.15 Changing the Output Status
*1
*3
DISPLAY
UTILITY
L
R1
C
S
NAME
[HAND1
]
[
]
[
]
[
]
Select the desired