YASKAWA Motoman UP6 Instructions Manual page 529

Controller and manipulator
Table of Contents

Advertisement

AL-4314 (SERIAL ENCODER BATTERY ERROR)
Since a serial encoder does not have a capacitor in the motor, the
data for accumulated rotation in the motor is lost if the control power
supply is turned OFF when the battery voltage is low.
Replace the battery immediately.
When the battery alarm occurs and the data for the accumulated
rotation is lost, perform zero-point positioning, paying attention to the
robot's working envelope before restarting the operation.
SERVOPACK
CNPG456
CNPG123
Fig. 36
An alarm
occurs.
Replace the battery.
Alarm?
Yes
Check the battery cable
(disconnection, etc.).
Alarm?
Yes
Remove connectors CNPB123 and
CNPB456 of the WRCA01 circuit board
and re-insert them. (See Fig. 36.)
Alarm?
Yes
Contact your Yaskawa
representative.
63
No
Continue normal operation.
The data was cleared because the
battery was low causing the alarm.
No
Continue normal operation.
The disconnected cable caused the alarm.
No
Continue normal operation.
A faulty connection caused the alarm.