Logical
Output Name / Function
Number
3010
RUNNING
This signal signifies that the job is running.
(Signifies that the job is running, system status
is waiting reserved start, or test run is running.)
This signal status is the same status as
[START] in the playback panel.
3011
SERVO IS ON
This signal signifies that the servo power is
turned ON, internal processing such as current
position creation is complete, and the system is
able to receive the START command. This sig
nal turns OFF when the servo power supply
turns OFF. It can be used for XRC status diag-
nosis for an external start.
3012
TOP OF MASTER JOB
This signal signifies that the execution position
is the top of the master job. This signal can be
used to confirm that the master job has been
*2
called.
3013
ALARM/ERROR OCCURRED
This signal signifies that an alarm or an error
occurred. If a major error occurs, this signal
remains ON until the main power is turned
OFF.
3014
BATTERY ALAR
This signal turns ON to notify that the battery
requires replacing when the voltage drops from
the battery for backup memory of the encoder.
Major problems may result if memory data is
lost because of an expired battery. It is recom-
mended to avoid these problems by using this
signal as a warning signal.
3015 t
REMOTE/PLAY/TEACH MODE SELECTED
3017
This signal notifies the current mode setting.
These signals are synchronized with the lamps
[REMOTE] and [MODE] in the playback panel.
The signal corresponding to the selected mode
turns ON.
3020
IN CUBE 1
This signal turns ON when the current tool cen
ter point lies inside a pre-defined space (Cube
1). Use this signal to prevent interference with
other manipulators and jigs.
*1
The operation origin cube and Cube 24 are same.
*2
This signal is not output during operation.
Specific Output List XIU01 (Handling)
Logical
Number
3021
3022
3023
3040 to
3047
7-35
7.5 General I/O Signal Assignment
Output Name / Function
IN CUBE 2
This signal turns ON when the current tool cen-
ter point lies inside a pre-defined space (Cube
2). Use this signal to prevent interference with
other manipulators and jigs.
OPERATION ORIGIN POINT (IN CUBE 24)
This signal turns ON when the current tool cen-
ter point lies inside a the operation origin area.
Use this signal to evaluate whether the robot is
in the start position.
INTERMEDIATE START OK
This signal turns ON when the manipulator
operates. It turns OFF when the currently exe-
cuted line is moved with the cursor or when
editing operation is carried out after HOLD is
applied during operation. Therefore, this signal
can be used as a restart interlock after a HOL
is applied. However, it also turns ON in the
TEACH mode and TEACH MODE SELECTED
signal must be referred together.
HAND VALVE 1-4
These outputs are controlled by the HAND
handling specific instructions.
Hand valves 1 to 4 correspond to HAND 1 to 4.
*1