Refer to:
–
Flag 2.
–
GP 13 How to Check a Switch.
–
P/J434, HCSS PWB.
•
Check the wiring, GP 7.
•
If necessary, install a new front door interlock switch, PL 11.56 Item 1.
11-304-130 Upper Exit Gate Interlock RAP
Check the upper exit gate interlock switch, S11-304, Figure 1.
•
Check the switch actuator.
•
Enter dC330, code 11-304, actuate the switch and check the display.
Refer to:
–
Flag 3.
–
GP 13 How to Check a Switch.
–
P/J434, HCSS PWB.
•
Check the wiring to the switch, GP 7.
•
If necessary, install a new upper exit gate interlock switch, PL 11.32 Item 9.
11-305-130 Lower Exit Gate Interlock RAP
Check the lower exit gate interlock switch, S11-305, Figure 2:
•
Check the switch actuator.
•
Enter dC330, code 11-305, actuate the switch and check the display.
Refer to:
–
Flag 3.
–
GP 13 How to Check a Switch.
–
P/J434, HCSS PWB.
•
Check the wiring to the switch, GP 7.
•
If necessary, install a new lower exit gate interlock switch, PL 11.54 Item 2.
WorkCentre 5687 Family
Upper exit gate
interlock switch,
S11-304
HCSS power
supply module
Figure 1 Component location
August 2007
11-300-130, 11-303-130, 11-304-130, 11-305-130
2-415
Front door
interlock
switch, S11-303
Docking Interlock
switch, S11-300
Docking pivot Interlock
switch, S11-300
Status Indicator RAPs