Testing; Test Mode; Entering Test Mode; Test Modes - Siemens Codoor CD3500 Installation & User Manual

Hide thumbs Also See for Codoor CD3500:
Table of Contents

Advertisement

Available languages

Available languages

CD3500 & CD4000 Installation and User manual

Testing

It must always be possible to open the door from the inside.
The handle on the outside should not be disengaged, and should
not open the door until the correct code is entered.
When the correct code is entered, the handle on the outside should
activate the lock, but only once. As the handle is released, it should
again disengage.
The handle on the outside must not be jammed in any position, and
should spring back up completely after being pressed down.
If the code is entered, Codoor should automatically reset to the
disengaged position after about 4 seconds.

Test Mode

A test mode is implemented primarily to test and set up the unit,
and also for field service. The unit will remain in test mode until the
appropriate command is given to leave it. It is not necessary to put the
processor into SLEEP mode other than by specific function.

Entering test mode

Test mode is entered by holding the button in at the rear of the unit
and pressing * for at least 2 seconds. The buzzer will give a short beep
and the green LED will be lit continuously, unless otherwise stated, to
indicate test mode. Each time a key is pressed the buzzer should be
sounded and the red LED lit as per normal operation.
Pressing one of the keys as follows then enters each test.

Test modes

Button 1
Button 2
Flashes the green and red LEDs simultaneously with the
sounding of the buzzer. This will continue until another key
is pressed.
Checks the RAM of the processor. If successful a confirm
tone is given or if unsuccessful an error tone is given. The
unit returns to test mode with the green LED continuously
lit.