Chapter 4 Display and Operation
Figure 4.6
NOTE
1) As the display of P4-06 is hexadecimal, 0(zero) of the fifth digit will not show on the LED
display.

4.4.4 DI Diagnosis Operation

Following the setting method in Figure 4.7 can perform DI diagnosis operation (parameter
P4-07, Input Status). According to the ON and OFF status of the digital inputs DI1 to DI8,
the corresponding status will display on the servo drive LED display. When the Bit is set to
"1", it means that the corresponding digital input signal is ON. (Please also refer to Figure
4.7)
For example:
Suppose that the servo drive LED display is "3FE1".
"E" is hexadecimal, which is equal to "1110" in binary system, and it means that the
digital inputs DI6 ~ DI8 are ON.