Delta ASDA-A2 Series User Manual page 394

High resolution ac servo drive for network communication applications
Hide thumbs Also See for ASDA-A2 Series:
Table of Contents

Advertisement

A2
ASDA-
P2-23
NCF1
Operation
Interface:
Default: 1000
Control
Range: 50 ~ 1000
Data Size: 16-bit
Display
Format:
Settings:
This parameter is used to set first resonance frequency of mechanical system. It
can be used to suppress the resonance of mechanical system and reduce the
vibration of mechanical system.
If P2-24 is set to 0, this parameter is disabled.
The parameters P2-23 and P2-24 are the first group of notch filter parameters
and the parameters P2-43 and P2-44 are the second group of notch filter
parameters.
P2-24
DPH1
Operation
Interface:
Default: 0
Control
Range: 0 ~ 32 (0: Disabled)
Data Size: 16-bit
Display
Format:
Settings:
This parameter is used to set magnitude of the resonance suppression that is set
by parameter P2-23. If P2-24 is set to 0, the parameters P2-23 and P2-24 are
both disabled.
The parameters P2-23 and P2-24 are the first group of notch filter parameters
and the parameters P2-43 and P2-44 are the second group of notch filter
parameters.
Revision September 2012
Notch Filter 1 (Resonance Suppression)
Keypad/Software
ALL
Mode:
Unit: Hz
Decimal
Notch Filter Attenuation Rate 1
(Resonance Suppression)
Keypad/Software
ALL
Mode:
Unit: dB
Decimal
Chapter 8 Servo Parameters
Communication
Communication
Address: 022EH
022FH
Related Section:
Section 6.3.7
Address: 0230H
0231H
Related Section:
Section 6.3.7