Chapter 8 Servo Parameters
The operation of parameter P0-35 is described as follows:
When PH ≠ PL, it indicates that P0-25 includes two 16-bit parameters.
VH = *(PH), VL = *(PL)
When PH = PL = P, it indicates that the content of P0-25 is one 32-bit parameter.
V32 = *(P). If P = 060Ah (parameter P6-10), the value of V32 is the value of P6-10.
A: Parameter group code in hexadecimal format
B: Parameter number in hexadecimal format
For example:
If the desired read and write parameter number is P2-06, please set P0-35 to
0206. If the desired read and write parameter number is P5-42, please set P0-35
to 052A, and vise versa.
When the users want to read and write the value of the parameter P1-44 (32-bit
parameter) via P0-25, please set P0-35 to 0x012C012C through communication
setting or the keypad. The the value of the parameter P1-44 will be displayed by
P0-25.
When the users want to read and write the values of the parameters P2-02
(Position Feed Forward Gain, 16-bit parameter) and P2-04 (Proportional Speed
Loop Gain, 16-bit parameter) via P0-25, please set P0-35 to 0x02040202 through
communication setting or the keypad. The the values of the parameters P2-02
and P2-04 will be displayed by P0-25.