Chapter 6 Control Modes of Operation
2. When the source of speed command is analog command, the maximum setting
value of P1-34 is limited to 20000 automatically.
P1-35
TDEC
Operation
Interface:
Default: 200
Control
Mode:
Range: 1 ~ 65500
Data Size: 16-bit
Display
Format:
Settings:
This parameter is used to determine the acceleration time to accelerate from 0 to its
rated motor speed. The functions of parameters P1-34, P1-35 and P1-36 are each
individual. When P1-36 is set to 0 (Disabled), the settings of P1-34, P1-35 are still
effective. It indicates that the parameters P1-34 and P1-35 will not become disabled
even when P1-36 is disabled.
Please note:
1. When the source of speed command is analog command, the maximum setting
value of P1-36 is set to 0, the acceleration and deceleration function will be
disabled.
2. When the source of speed command is analog command, the maximum setting
value of P1-35 is limited to 20000 automatically.
P1-36
TSL
Operation
Interface:
Default: 0
Control
Mode:
Range: 0 ~ 65500 (0: Disabled)
Data Size: 16-bit
Display
Format:
Settings:
This parameter is used to make the motor run more smoothly when startup and
windup. Using this parameter can improve the motor running stability.
6-12
Deceleration Time
Keypad/Software
S
Unit: ms
Decimal
Accel /Decel S-curve
Keypad/Software
S, PR
Unit: ms
Decimal
Communication
Communication
Address: 0146H
0147H
Related Section:
Section 6.3.3
Address: 0148H
0149H
Related Section:
Section 6.3.3
Revision September 2012