Chapter 8 Servo Parameters
Settings:
This position will be synchronized with the capture signal. When capture
operation is actived every two times, the offset value of this SYNC axis will be
equal to the value of P5-78 (no accumulation errors, for single direction
operation only).
This parameter can be used as the position source of E-Cam master axis.
Please note:
ASDA-A2 series L type models do not provide Electronic Cam (E-Cam) function.
P5-78
CSDS
Operation
Interface:
Default: 100
Control
Mode:
Range: 10 ~ +100000000
Data Size: 32-bit
Display
Format:
Settings:
This parameter is used to set the offset value of this SYNC axis when capture
operation is activated every two times.
Please note:
1. This parameter can be set only when capture operation is stopped (Refer to
P5-39).
2. ASDA-A2 series L type models do not provide Electronic Cam (E-Cam)
function.
P5-79
CSDS
Operation
Interface:
Default: 0
Control
Mode:
Range: -2147483648 ~ +2147483647
Data Size: 32-bit
Display
Format:
Settings:
This parameter is used to display the error pulse number of CAPTURE SYNC AXIS
operation.
8-208
Interval Pulse Number of CAPTURE SYNC
AXIS
Keypad / Software
ALL
Unit: pulse
Decimal
Error Pulse Number of CAPTURE SYNC AXIS
Keypad / Software
ALL
Unit: pulse
Decimal
Communication
Communication
ASDA-
Address: 059CH
059DH
Related Section: N/A
Address: 059EH
059FH
Related Section: N/A