Delta ASDA-A2 Series User Manual page 406

High resolution ac servo drive for network communication applications
Hide thumbs Also See for ASDA-A2 Series:
Table of Contents

Advertisement

A2
ASDA-
P2-45
NCF3
Operation
Interface:
Default: 1000
Control
Range: 50 ~ 2000
Data Size: 16-bit
Display
Format:
Settings:
This parameter is used to set third resonance frequency of mechanical system. It
can be used to suppress the resonance of mechanical system and reduce the
vibration of mechanical system.
If P2-46 is set to 0, this parameter is disabled.
P2-46
DPH3
Operation
Interface:
Default: 0
Control
Range: 0 ~ 32
Data Size: 16-bit
Display
Format:
Settings:
This parameter is used to set magnitude of the resonance suppression that is set
by parameter P2-45. If P2-46 is set to 0, the parameters P2-45 and P2-46 are
both disabled.
Revision September 2012
Notch Filter 3 (Resonance Suppression)
Keypad/Software
ALL
Mode:
Unit: Hz
Decimal
Notch Filter Attenuation Rate 3
(Resonance Suppression)
Keypad/Software
ALL
Mode:
Unit: dB
Decimal
Chapter 8 Servo Parameters
Communication
Communication
Address: 025AH
025BH
Related Section:
Section 6.3.7
Address: 025CH
025DH
Related Section:
Section 6.3.7