Chapter 6 Control Modes of Operation
P2-45
NCF3
Operation
Interface:
Default: 1000
Control
Mode:
Range: 50 ~ 2000
Data Size: 16-bit
Display
Format:
Settings:
This parameter is used to set third resonance frequency of mechanical system. It
can be used to suppress the resonance of mechanical system and reduce the
vibration of mechanical system.
If P2-46 is set to 0, this parameter is disabled.
P2-46
DPH3
Operation
Interface:
Default: 0
Control
Mode:
Range: 0 ~ 32
Data Size: 16-bit
Display
Format:
Settings:
This parameter is used to set magnitude of the resonance suppression that is set
by parameter P2-45. If P2-46 is set to 0, the parameters P2-45 and P2-46 are
both disabled.
6-42
Notch Filter 3 (Resonance Suppression)
Keypad/Software
ALL
Unit: Hz
Decimal
Notch Filter Attenuation Rate 3
(Resonance Suppression)
Keypad/Software
ALL
Unit: dB
Decimal
Communication
Communication
Address: 025AH
025BH
Related Section:
Section 6.3.7
Address: 025CH
025DH
Related Section:
Section 6.3.7
Revision September 2012