Chapter 4 Panel Display and Operation ASDA-A2R Series

4.4.4 Digital Input Diagnosis Operation

Enter into the Digital Input Diagnosis Mode by the following setting methods. When the
external output signal DI1~DI8 is ON, the corresponding signal will be shown on the
panel. It is displayed by bit. When it shows bit, it means it is ON.
For example, if it shows 3FE1 , E is in hexadecimal format, it will be 1100 when it transfers
to binary format. Then, DI6~DI8 is ON.

4.4.5 Digital Output Diagnosis Operation

Enter into the Digital Output Diagnosis Mode by the following setting methods. The
output signal DO1~DO5 is ON and the corresponding signal will be shown on the panel.
It is displayed by bit. When it shows bit, it means it is ON.
For example, if it shows 1F , F is in hexadecimal format, it will be 1111 when it transfers to
binary format. Then, DO1~DO4 is ON.
4-12
SET
DI
DI
DI
DI
DI
DI
DI
DI
DI
14
13
12
11
10
9
8
7
6
(Display in hexadecimal format)
SET
The panel displays in
hexadecimal format
DO
DO
DO
5
4
3
(Display in hexadecimal format)
The panel displays in
hexadecimal format.
DI
DI
DI
DI
DI
5
4
3
2
1
Binary code
Corresponding
DO
DO
2
1
DO status
Binary code
Corresponding
DI status
Revision December, 2014