4.4.4 Digital Input Diagnosis Operation

Enter the Diagnosis Mode – DI by the following setting methods. When the external output signal
DI1 ~ DI5 is ON, the corresponding signal will be shown on the panel. It is displayed by bit. When
it shows bit, it means the DI is ON.
For example, if it shows 001E, E is in hexadecimal format, it will be 1110 when it transfers to
binary format. Then, DI2 ~ DI4 is ON.
September, 2015
SET
00 0000 0001 1110
DI
DI
DI
DI
DI
DI
DI
DI
DI
14
13
12
11
10
9
8
7
6
(Display in hexadecimal format)
The panel displays in
hexadecimal format.
Binary code
Corresponding
DI
DI
DI
DI
DI
5
4
3
2
1
Panel Display and Operation