Chapter 8 Servo Parameters
P5-85
ECME
Operation
Interface:
Default: 0
Control
Mode:
Range: 0 ~ ( P5-82 -1 )
Data Size: 16-bit
Display
Format:
Settings:
This parameter is used to set the E-Cam area number when the electronic gear is
engaged.
Please note:
ASDA-A2 series L type models do not provide Electronic Cam (E-Cam) function.
P5-86
ECAX
Operation
Interface:
Default: 0
Control
Mode:
Range: -2147483648 ~ +2147483647
Data Size: 32-bit
Display
Format:
Settings:
This parameter is used to set the position of E-Cam master axis.
Please note:
1. This parameter can be set only when E-Cam function is stopped (Refer to P5-88).
2. ASDA-A2 series L type models do not provide Electronic Cam (E-Cam) function.
8-212
E-Cam: Engage Area Number
Keypad / Software
PR
Unit: N/A
Decimal
E-Cam: Position of Master Axis
Keypad / Software
PR
Unit: N/A
Decimal
Communication
Communication
ASDA-
Address: 05AAH
05ABH
Related Section:
Section 7.11
Address: 05ACH
05ADH
Related Section:
Section 7.11
Revision September 2012