Chapter 8 Servo Parameters
P5-73
POV13 Moving Speed Setting of Position 13
Operation
Interface:
Default: 2300.0
Control
Mode:
Range: 0.1 ~ 6000.0
Data Size: 16-bit
Display
Format:
Input Value
Example:
Settings:
In PR mode, this parameter is used to set the moving speed for the fourteenth
position.
P5-74
POV14 Moving Speed Setting of Position 14
Operation
Interface:
Default: 2500.0
Control
Mode:
Range: 0.1 ~ 6000.0
Data Size: 16-bit
Display
Format:
Input Value
Example:
Settings:
In PR mode, this parameter is used to set the moving speed for the fifteenth
position.
8-206
Keypad / Software
PR
Unit: 1 r/min
Decimal
1 = 1 r/min
Keypad / Software
PR
Unit: 1 r/min
Decimal
1 = 1 r/min
Communication
23000
0.1 r/min
1 ~ 60000
10 = 1 r/min
Communication
25000
0.1 r/min
1 ~ 60000
10 = 1 r/min
ASDA-
Address: 0592H
0593H
Related Section:
Section 7.10
Address: 0594H
0595H
Related Section:
Section 7.10
Revision September 2012