Backup Battery Boxes; Specifications - Delta ASDA-A2 Series User Manual

High resolution ac servo drive for network communication applications
Hide thumbs Also See for ASDA-A2 Series:
Table of Contents

Advertisement

A2
ASDA-
12.1

Backup Battery Boxes

12.1.1 Specifications

Precautions
Please thoroughly understand and observe the following safety precautions. Failure to
observe these precautions may void warranty! In order to prevent damage and danger,
please use batteries in accordance with the specified specification.
 Do not use the product in a potentially explosive environment. Install the product in a clean
and dry location free from corrosive and inflammable gases or liquids.
 Do not place the battery dispersedly to prevent short circuiting and accidents.
 Do not short circuit the positive pole and the negative pole of the batteries or install
batteries in reverse polarity.
 To prevent electric energy loss and lifetime reduction, it is recommended to use new
batteries only.
 Do not store batteries within an ambient temperature above +100°C. Failure to observe
this precaution may cause fire or explosion.
 The batteries are non-rechargeable. Do not charge the batteries or explosion may result.
 Do not directly solder the battery surface.
Battery Specifications
Items
Model Number
Delta Model Number
International Standard Size
Nominal Voltage
Nominal Capacity
Maximum Continuous
Operating Current
Maximum Pulse Current
Dimensions (D x H)
Weight
Operating Temperature
12-2
Chapter 12 Absolute System
Li/SOCl2 Cylindrical Battery
ER14505
ASD-CLBT0100
AA
3.6V
2700mAh
100 mA
200 mA
14.5 x 50.5mm
Approx. 19g
-40 ~ +85°C
Revision September 2012