A2
ASDA-
P2-27
GCC
Operation
Interface:
Default: 0
Control
Range: 0 ~ 4
Data Size: 16-bit
Display
Format:
Settings:
Gain Switching Condition Settings:
A: Gain Switching Condition Settings:
0: Disabled
1: Gain switching DI (Digital Input) signal (GAINUP) is On. (see Table 8.A)
2: In position mode, position deviation is higher than the setting value of P2-29.
3: Position command frequency is higher than the setting value of P2-29.
4: Servo motor speed is higher than the setting value of P2-29.
5: Gain switching DI (Digital Input) signal (GAINUP) is Off. (see Table 8.A)
6: In position mode, position deviation is lower than the setting value of P2-29.
7: Position command frequency is lower than the setting value of P2-29.
8: Servo motor speed is lower than the setting value of P2-29.
B: Gain Switching Control Settings:
0: Gain multiple switching
1: P  PI switching
Setting
0
1
Revision September 2012
Gain Switching Control Selection
Keypad/Software
ALL
Mode:
Unit: N/A
Hexadecimal
P mode
P2-00 x 100%
P2-04 x 100%
P2-00 x P2-01
P2-04 x P2-05
P2-06 x 0%
P2-26 x 0%
P2-06 x 100%
P2-26 x 100%
Communication
S mode
P2-04 x 100%
P2-04 x P2-05
Chapter 8 Servo Parameters
Address: 0236H
0237H
Related Section: N/A
Status
Before switching
After switching
Before switching
After switching
8-119