Chapter 10 Troubleshooting

10.4 Absolute System Fault Messages Table

Display
Fault Name
Voltage level
above
specification
Gray code error
Absolute
position lost
Voltage level
below
specification
Overflow
warning of
absolute
position
I/O data
transmission
error of
absolute
position
Motor type
error
Position
counter
overflow
NOTE
1) If there is any unknown fault code that is not listed on the above table, please inform the
distributor or contact with Delta for assistance.
2) For more information about the CANopen objects, please refer to CANopen Instruction Manual.
Revision September 2012
Fault Messages
Fault Description
The voltage level of the battery is
higher than the specified voltage
( > 3.8V). Maybe an electrical
charge still remains in the servo
drive.
An absolute position error within
one turn.
The recorded turn numbers are
lost as the voltage level of battery
is too low or after a power
interruption.
The voltage level of the battery is
lower than the specified voltage.
The normal range of turn
numbers of absolute position is -
32768~+32767.
A timing error occurs when
reading the data of absolute
position via the digital inputs and
outputs.
Possible an incremental type
motor is connected.
Possible the setting value of P2-69
is not set to 0.
Position counter overflow occurs.
ASDA-
Corresponding
Servo
Digital Output
Status
ALRM
Servo Off
(DO code: 0x07)
ALRM
Servo Off
(DO code: 0x07)
WARN
Servo On
(DO code: 0x11)
WARN
Servo On
(DO code: 0x11)
WARN
Servo On
(DO code: 0x11)
WARN
Servo On
(DO code: 0x11)
ALRM
Servo Off
(DO code: 0x07)
WARN
Servo On
(DO code: 0x11)
A2
10-9