Delta ASDA-A2 Series User Manual page 484

High resolution ac servo drive for network communication applications
Hide thumbs Also See for ASDA-A2 Series:
Table of Contents

Advertisement

A2
ASDA-
P5-75
POV15 Moving Speed Setting of Position 15
Operation
Interface:
Default: 3000.0
Control
Mode:
Range: 0.1 ~ 6000.0
Data Size: 16-bit
Display
Format:
Input Value
Example:
Settings:
In PR mode, this parameter is used to set the moving speed for the sixteenth
position.
P5-76★
CPRS
Operation
Interface:
Default: 0
Control
Mode:
Range: -1073741824 ~ +1073741823
Data Size: 32-bit
Display
Format:
Settings: Refer to P5-39 for explanation.
P5-77
CSAX
Operation
Interface:
Default: 0
Control
Mode:
Range: -2147483648 ~ +2147483647
Data Size: 32-bit
Display
Format:
Revision September 2012
Keypad / Software
PR
Unit: 1 r/min
Decimal
1 = 1 r/min
Capture 1st Position Reset Data
Keypad / Software
ALL
Unit: N/A
Decimal
Position of CAPTURE SYNC AXIS
Keypad / Software
ALL
Unit: N/A
Decimal
Chapter 8 Servo Parameters
Communication
30000
0.1 r/min
1 ~ 60000
10 = 1 r/min
Communication
Communication
Address: 0596H
0597H
Related Section:
Section 7.10
Address: 0598H
0599H
Related Section:
Section 7.10
Address: 059AH
059BH
Related Section: N/A
8-207

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents