Delta ASDA-A2 Series User Manual page 481

High resolution ac servo drive for network communication applications
Hide thumbs Also See for ASDA-A2 Series:
Table of Contents

Advertisement

Chapter 8 Servo Parameters
P5-69
POV9
Operation
Interface:
Default: 1300.0
Control
Mode:
Range: 0.1 ~ 6000.0
Data Size: 16-bit
Display
Format:
Input Value
Example:
Settings:
In PR mode, this parameter is used to set the moving speed for the tenth
position.
P5-70
POV10 Moving Speed Setting of Position 10
Operation
Interface:
Default: 1500.0
Control
Mode:
Range: 0.1 ~ 6000.0
Data Size: 16-bit
Display
Format:
Input Value
Example:
Settings:
In PR mode, this parameter is used to set the moving speed for the eleventh
position.
8-204
Moving Speed Setting of Position 9
Keypad / Software
PR
Unit: 1 r/min
Decimal
1 = 1 r/min
Keypad / Software
PR
Unit: 1 r/min
Decimal
1 = 1 r/min
Communication
13000
0.1 r/min
1 ~ 60000
10 = 1 r/min
Communication
15000
0.1 r/min
1 ~ 60000
10 = 1 r/min
ASDA-
Address: 058AH
058BH
Related Section:
Section 7.10
Address: 058CH
058DH
Related Section:
Section 7.10
Revision September 2012
A2

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents