Delta ASDA-A2 Series User Manual page 338

High resolution ac servo drive for network communication applications
Hide thumbs Also See for ASDA-A2 Series:
Table of Contents

Advertisement

A2
ASDA-
Please note:
1. When the source of pulse command is the high-speed linear driver signal and the setting
value B is set to 0 (High-speed Filter Frequency is 3.33Mpps):
If an input pulse of 2~4MHz is used, it is recommended to change the setting value B (Input
pulse filter) and set this setting value to 4. Please note that this function is available for DSP
version V1.036 sub05, CPLD version V10 and later models only.
Note: If the signal is a 4Mpps high input pulse, setting the value B to 4 is able to ensure
that the signal will not be filtered and will be certainly delivered.
Revision September 2012