Delta ASDA-A2 Series User Manual page 579

High resolution ac servo drive for network communication applications
Hide thumbs Also See for ASDA-A2 Series:
Table of Contents

Advertisement

A2
ASDA-
P3-01
BRT
Operation
Interface:
Default: 0x0203
Control
Mode:
Range: 0x0000 ~ 0x0405
Data Size: 16-bit
Display
Format:
Settings: This parameter is used to set the baud rate and data transmission
9-4
Please note:
1. When the address of host (external) controller is set to 0xFF, it
is with auto-respond function. Then, the servo drive will receive
from and respond to host (external) controller both no matter
the address is matching or not. However, the parameter P3-00
cannot be set to 0xFF.
Transmission Speed
Keypad / Software
ALL
Unit: bps
Hexadecimal
speed of the communications.
COM Port
Range
Settings:
Setting value of X: Baud rate setting
0: Baud rate 4800 (data transmission speed: bits / second)
1: Baud rate 9600 (data transmission speed: bits / second)
2: Baud rate 19200 (data transmission speed: bits / second)
3: Baud rate 38400 (data transmission speed: bits / second)
4: Baud rate 57600 (data transmission speed: bits / second)
5: Baud rate 115200 (data transmission speed: bits / second)
Setting value of Y: Reserved. Must be set to 0.
Setting value of Z: Data transmission speed setting
0: 125K bits / second
1: 250K bits / second
2: 500K bits / second
3: 750K bits / second
4: 1.0M bits / second
Communication
0
Z
-
CAN
0
0 ~ 4
Chapter 9 Communications
Address: 0302H
0303H
Related Section:
Section 9.2
Y
X
-
RS-232/485
0
0 ~ 5
Revision September 2012