Chapter 8 Servo Parameters
P5-10★
AYSZ
Operation
Interface:
Default: N/A
Control
Mode:
Range: Read only
Data Size: 16-bit
Display
Format:
Settings:
This parameter is used to set the data amount of data arrady (N x 32 bits). N is
the capacity of the data array.
P5-11
AYID
Operation
Interface:
Default: 0
Control
Mode:
Range: 0 ~ (P5-10-1)
Data Size: 16-bit
Display
Format:
Settings:
This parameter is used to set the data address when reading and writing data
array.
P5-12
AYD0
Operation
Interface:
Default: 0
Control
Mode:
Range: -2147483648 ~ +2147483647
Data Size: 32-bit
Display
Format:
8-178
Data Array: Data Amount (N x 32 bits)
Keypad / Software
ALL
Unit: N/A
Decimal
Data Array: Read / Write Address
Keypad / Software
ALL
Unit: N/A
Decimal
Data Array: Read / Write Data Block 1
Keypad / Software
ALL
Unit: N/A
Decimal
Communication
Communication
Communication
ASDA-
Address: 0514H
0515H
Related Section:
Section 7.2
Address: 0516H
0517H
Related Section:
Section 7.2
Address: 0518H
0519H
Related Section:
Section 7.2