Digital Input Diagnosis Operation; Digital Output Diagnosis Operation - Delta ASDA-B3 Series User Manual

Hide thumbs Also See for ASDA-B3 Series:
Table of Contents

Advertisement

Test Operation and Panel Display

4.4.3 Digital input diagnosis operation

You can switch to the Diagnosis mode by the following steps. When DI1 - DI9 are triggered by
the external signal, the panel shows the corresponding signal in bit. When it shows 1, it means
4
the DI is on.
For example, if it shows 1FE1, E is in hexadecimal format; it will be 1110 when it transfers to
binary format. Then, DI6 - DI8 are on.

4.4.4 Digital output diagnosis operation

You can switch to the Diagnosis mode by the following steps. When DO1 - DO6 are triggered by
the output signal, the panel shows the corresponding signal in bit. When it shows 1, it means
the DO is on.
For example, if it shows 1F, F is in hexadecimal format; it will be 1111 when it transfers to binary
format. Then, DO1 - DO4 are on.
4-12
SET
1 1 1 1 1 1 1 1 0 0 0 0 1
13
12 11 10 9
8
7 6 5
(Display in hexadecimal format)
SET
The panel displays in
hexadecimal format
0 0 0 1 1 1 1 1
5
4
3
2
1
(Display in hexadecimal format)
The panel displays in
hexadecimal format.
Binary code
Corresponding
4 3 2 1
DI status
Binary code
Corresponding
DO status
ASDA-B3

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents