A2
ASDA-

Table 8.A Input Function Definition

Setting value: 0x01
DI Name
Servo On. When this DI is activated, it indicates the
SON
servo drive is enabled.
Setting value: 0x02
DI Name
A number of Faults (Alarms) can be cleared by
activating ARST. Please see table 10-3 for applicable
faults that can be cleared with the ARST command.
ARST
However, please investigate Fault or Alarm if it does
not clear or the fault description warrants closer
inspection of the drive system.
Setting value: 0x03
DI Name
Gain switching in speed and position mode. When
GAINUP is activated (P2-27 is set to 1), the gain is
GAINUP
switched to the gain multiplied by gain switching
rate.
Setting value: 0x04
DI Name
When CCLR is activated, the setting parameter P2-50
Pulse Clear Mode is executed.
CCLR
0: After CCLR is activated (ON), the position
accumulated pulse number will be cleared
continuously.
Revision September 2012
DI Function Description
DI Function Description
DI Function Description
DI Function Description
Chapter 8 Servo Parameters
Trigger
Control
Method
Mode
Level
Triggered
Trigger
Control
Method
Mode
Rising-edge
Triggered
Trigger
Control
Method
Mode
Level
PT, PR, S
Triggered
Trigger
Control
Method
Mode
Rising-edge
Triggered,
PT, PR
Level
Triggered
All
All
8-281