Test Operation and Panel Display
4.4.3 Digital input diagnosis
You can switch to the Diagnosis mode by the following steps. When DI1 - DI9 are triggered by
the external signal, the panel shows the corresponding signal. In binary format, when the bit
4
shows 1, it means the DI is on.
For example, if the panel shows "1FE1", the hexadecimal E is 1110 in binary format, indicating
that DI6 - DI8 are on.
4.4.4 Digital output diagnosis
You can switch to the Diagnosis mode by the following steps. When DO1 - DO6 are triggered by
the output signal, the panel shows the corresponding signal. In binary format, when the bit
shows 1, it means the DO is on.
For example, if the panel shows "1F", the hexadecimal F is 1111 in binary format, indicating that
DO1 - DO4 are on.
4-12
SET
The panel displays in
hexadecimal format
Binary code
Corresponding DO
5
4
3
2
1
ASDA-B3