Advertisement

Chapter 8 Servo Parameters
Settings:
This parameter is used to determine the drive status found in P0-02. For the
setting values, please refer to section 7.2.1 Monitoring Variables. The selected
drive status will be displayed by P0-13. Refer to P0-17 for explanation.
P0-22
Reserved (Do Not Use)
P0-23
Reserved (Do Not Use)
P0-24
Reserved (Do Not Use)
P0-25
MAP1 Mapping Parameter 1
Operation
Interface:
Default: N/A, initialization is not required
Control
Range: determined by the parameter specified by
Data Size: 32-bit
Display
Format:
Settings:
The parameters from P0-25 to P0-32 are used to read and write the values of the
parameters those communication addresses are not consecutive. The users can
set P0-35 ~ P0-42 as the desired read and write mapping parameter numbers
through communication setting or the keypad.
When reading or writing P0-25 ~ P0-32, the read or write values are equivalent to
the values of the parameters specified by P0-35 ~ P0-42, and vise versa.
Refer to P0-35 for explanation.
8-44
Keypad/Software
ALL
Mode:
Unit: -
P0-35
Hexadecimal
Communication
ASDA-
Address: 002CH
002DH
Address: 002EH
002FH
Address: 0030H
0031H
Address: 0032H
0033H
Related Section:
Section 4.3.5
Revision September 2012
A2