Delta ASDA-A2 Series User Manual page 566

High resolution ac servo drive for network communication applications
Hide thumbs Also See for ASDA-A2 Series:
Table of Contents

Advertisement

A2
ASDA-
Setting value: 0x43, 0x44
DI Name
Electronic gear ratio (Numerator) selection 0 ~ 1 [see
P2-60 ~ P2-62]
GNUM0
GNUM1
Setting value: 0x45
DI Name
Pulse inhibit input. When the drive is in position
mode, if INHP is activated, the external pulse input
INHP
command is not valid. (Please use DI8 for INHP
signal to ensure the real-time operation of INHP
function.)
Setting value: 0x46
DI Name
STOP
Motor stop.
NOTE
1) 11 ~ 17: Single control mode, 18 ~ 20: Dual control mode
2) When P2-10 to P2-17 is set to 0, it indicates input function is disabled.
Revision September 2012
DI Function Description
DI Function Description
DI Function Description
Chapter 8 Servo Parameters
Trigger
Control
Method
Mode
Level
Triggered
Trigger
Control
Method
Mode
Level
Triggered
Trigger
Control
Method
Mode
Rising-edge
Triggered
PT
PT
PR
8-289

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents