Automatic Transmission
S y s t e m D e s c r i p t i o n ( c o n t ' d )
Hydraulic Flow (cont'd)
D and D3 Positions: Driving i n l s t gear
The PCM turns shift solenoid valve C O N , and shift solenoid valve C covers the port of shift solenoid valve C pressure
(SC) t o the shift valves C and D. Shift solenoid valve A keeps OFF, and shift solenoid valve B keeps ON. The shift
valves C and D are m o v e d to the left side, the shift valve D switches the port of line pressure (4) and CPC C pressure
(4C) leading to the 1st clutch, and the shift valve C switches the port of CPC A pressure (5A) releasing 2nd clutch
pressure. Line pressure (4) becomes 1st clutch pressure (10) at the shift valve D, and f l o w s to the 1st clutch. The 1st
clutch is engaged securely w i t h the line pressure mode.
NOTE: W h e n used, " l e f t " or " r i g h t " indicates direction on the hydraulic circuit.