Honda ACCORD HYBRID 2005 Service Manual page 590

Hide thumbs Also See for ACCORD HYBRID 2005:
Table of Contents

Advertisement

Fuel Supply System
D T C T r o u b l e s h o o t i n g (cont'd)
46. Check for continuity between fuel p u m p control
module 10P connector terminal No. 7 and body
g r o u n d .
F U E L PUMP CONTROL M O D U L E 10P CONNECTOR
/
3
4
5
6
7
8
/ /
F P - (LT BLU)
W i r e side of female t e r m i n a l s
Is there
continuity?
YES—Repair short in the w i r e between the fuel
p u m p control module (FP— line) and the fuel p u m p ,
then g o t o step 67.
NO—Substitute a known-good fuel p u m p control
m o d u l e (see page 11 -370), then go to step 67 and
recheck. If DTC P0627 is not indicated, replace the
original fuel p u m p control m o d u l e (see page
11 -370), then go to step 67. If DTC P0627 is
indicated, go to step 73.
47. Turn the ignition switch OFF.
48. Disconnect the fuel p u m p control module 10P
connector (see page 11-370).
49. Check for continuity between fuel p u m p control
module 10P connector terminal No. 8 and body
ground.
F U E L PUMP CONTROL MODULE 10P C O N N E C T O R
/ /
3 4
5
6
7
8
/ /
GND (BLK)
W i r e side of female terminals
Is there
continuity?
Y E S — G o t o step 50.
NO—Repair open in the w i r e between the fuel
p u m p control module (GND line) and G602, then go
to step 67.
50. Check for continuity between fuel p u m p control
module 10P connector terminal No. 5 and body
ground.
F U E L PUMP CONTROL M O D U L E 10P CONNECTOR
/ /
3
4
5
6
7
8
/
FPC (BLU)
Wire side of f e m a l e terminals
Is there
continuity?
Y E S — G o t o step 5 1 .
N O — G o t o step 54.
11-350