17. Turn the ignition switch ON (II), and measure
voltage between fuel p u m p control module 10P
connector terminal No. 3 and body g r o u n d w i t h i n
2 seconds.
F U E L PUMP CONTROL MODULE 10P CONNECTOR
/
3
4
6
7
8
/
IG1 (RED/YEL)
W i r e side of female terminals
Is there battery
voltage?
YES—Go to step 18.
N O -
• Repair open in the wire between the under-dash
fuse/relay box and the fuel p u m p control module,
then go to step 67.
• If needed, replace the under-dash fuse/relay box
(see page 22-70), then go to step 67.
18. Turn the ignition switch OFF.
19. J u m p the SCS line with the HDS.
20. Disconnect PCM connector E (31P).
21. Connect PGM-FI main relay 2 (FUEL PUMP) 4P
connector terminal No. 4 to body ground w i t h a
j u m p e r w i r e .
PGM-FI MAIN RELAY 2 (FUEL PUMP) 4P CONNECTOR
4
IMOFPR
J U M P E R WIRE
Terminal side of female terminals
22. Check for continuity between PCM connector
terminal E2 and body g r o u n d .
PCM CONNECTOR E (31P)
IMOFPR (BRN)
1
2
3
4
I
5
6
7
8
9
10 11 12 13 14 15 16 17 18 19 20 21
22 23 24
25 26
27
/
29
/
31
W i r e side of female terminals
Is there
continuity?
Y E S — G o t o step 73.
NO—Repair open in the w i r e between the PCM (E2)
and PGM-FI main relay 2 (FUEL PUMP), then go to
step 67.
(cont'd)
11-347