Chapter 5 System Settings and Display
5.2 Network Management > set event-notification

set event-notification

This command sets up the parameters for event notification, primarily the notification targets such as E-mail,
SNMP traps, host sense, REMCS, syslog, and AIS Connect. Notification targets for specific events can be set
individually, all events of a particular level can be set to be notified in the same way, or one of two preset
options can be selected. When selecting either of the two preset values, other parameters cannot be
specified.
Syntax
set event-notification
{-preset {system-default | remcs-default} |
{-severity {error | warning | information | e-parts-error | e-disk-error | e-temperature-error | e-battery-life |
e-rebuild-copyback-with-redundant | e-rebuild-copyback-without-redundant |
e-complete-redundant-copy | e-complete-rebuild | e-bad-data | e-pinned-data | e-not-ready |
e-remote-path-with-transfer | e-remote-path-without-transfer | e-halt-path | e-halt-overload |
e-halt-other | e-tp-pool-ratio | e-redundant | e-copy-session-error | e-sed-network-error | e-nas-io-error |
e-tfo-state-auto-changed | e-tfo-state-manual-changed | e-storage-cluster-controller-disconnected |
w-parts-warning | w-disk-warning | w-temperature-warning | w-battery-life | w-nas-io-warning |
w-nas-connection-error | w-out-of-nas-capacity | i-recovery-module | i-temperature-restoration |
i-user-logon-logoff | i-operate-raid-group | i-add-release-hot-spare | i-operate-volume | i-power-off-on-cfl |
i-sdp-policy-level1 | i-sdp-policy-level2 | i-sdp-policy-level3 | i-limit-copy-table |
i-expire-trial-copy-license | i-odx | i-sed-network-error-recovered | i-fc-ca-port-link-status-changed |
i-host-login-over | i-remote-path-recovered | i-nas-connection-status | i-out-of-nas-capacity |
i-out-of-nas-file-management-domain | i-storage-cluster-controller-connected}
-method {email | snmp | host | remcs | syslog| ais}
-suppression {enable | disable | disable-when-no-hs}
[-host-sense-opmsg {enable | disable}]}
Parameter
-preset
This parameter specifies preset settings for event notification values. If this parameter is
selected, other parameters cannot be specified. The default values are described in the
examples below:
system-default
Set the system default (Factory shipping default).
remcs-default
Set the remote service default (recommended REMCS operation value).