Appendix A Error Messages/Error Codes
A.1 Error Messages
Message
number
ED544
ED545
ED546
ED548
ED549
ED54A
ED54B
ED54C
ED54D
ED54E
ED54F
ED550
ED551
ED552
ED553
ED554
ED555
ED700
ED701
Volume that can not be use in TFO pair port exists.
A volume that cannot configure a TFO pair port exists.
Failover mode or Split mode does not match between the secondary and primary.
The operation mode (Failover Mode, Split Mode) in the Primary storage and the Secondary storage does
not match.
Copy session exists in the volume.
The copy session exists in the volume.
Volume UID differs with in the secondary and primary.
The UID in the Primary storage and Secondary storage is inconsistent.
Can not to delete TFO group that is changed WWN in the standby state.
For TFO groups in a Standby state, WWPN was deleted permanently.
Volume of primary paired with specified volume is not exist.
The volume that will be paired with the specified volume in the Primary storage does not exist.
TFO group activation was specified for incorrect device.
An ETERNUS DX (Primary storage or Secondary storage) that has no relevance was specified for activation.
Port of primary paired is not affinity setting.
The primary pair port is not set with host affinity.
Storage Cluster data transfer feature is disabled in all RA ports constituting the copy path.
For all RA ports that constitute the copy path, the data transfer for the Storage Cluster function is set to
disable.
TFO pair is active.
The TFO pair exists.
Device of manual failover is inappropriate TFO group condition.
The manual failover target storage system is in an inappropriate TFO group state.
The volume cannot be set the copy.
The LU for the copy source or copy destination is in a state in which the copy session cannot be set.
There is "Bad Sector" in the copy source volume.
A bad sector exists in the copy source LU.
The number of copy sessions exceeds the allowable maximum copy sessions for this storage.
The maximum number of sessions per copy source or copy destination ETERNUS DX storage systems has
been exceeded.
The number of copy sessions exceeds the allowable maximum copy sessions for each copy source volume.
The maximum number of sessions per copy source LU has been exceeded.
The number of copy sessions exceeds the allowable maximum copy sessions for each copy destination
volume.
The maximum number of sessions per copy destination LU has been exceeded.
Firmware update is in progress. The specified operation cannot be done.
The command cannot be executed during an active update for the controller firmware in the copy source
or copy destination.
The free capacity of the NAS volumes is insufficient.
The free capacity of the NAS volumes is insufficient.
The free capacity of the NAS system volumes is insufficient.
The free capacity of the NAS system volumes is insufficient.